Description of Function Codes
MD380 User Manual
- 188 -
)unction Code Parameter Name Setting Range Default
)8-03 Acceleration time 2 0.0–6500.0s Model dependent
)8-04 Deceleration time 2 0.0–6500.0s Model dependent
)8-05 Acceleration time 3 0.0–6500.0s Model dependent
)8-06 Deceleration time 3 0.0–6500.0s Model dependent
)8-07 Acceleration time 4 0.0–500.0s Model dependent
)8-08 Deceleration time 4 0.0–6500.0s Model dependent
The MD380 provides a total of four groups of acceleration/deceleration time, that is,
WKHSUHFHGLQJWKUHHJURXSVDQGWKHJURXSGHILQHGE\)DQG)'HILQLWLRQVRI
four groups are completely the same. You can switch over between the four groups of
DFFHOHUDWLRQGHFHOHUDWLRQWLPHWKURXJKGLIIHUHQWVWDWHFRPELQDWLRQVRI',WHUPLQDOV)RUPRUH
GHWDLOVVHHWKHGHVFULSWLRQVRI)WR)
)unction Code Parameter Name Setting Range Default
)8-09 Jump frequency 1 0.00 Hz to maximum frequency 0.00 Hz
)8-10 Jump frequency 2 0.00 Hz to maximum frequency 0.00 Hz
)8-11 )requency jump amplitude 0.00 Hz to maximum frequency 0.00 Hz
If the set frequency is within the frequency jump range, the actual running frequency is the
jump frequency close to the set frequency. Setting the jump frequency helps to avoid the
mechanical resonance point of the load.
The MD380 supports two jump frequencies. If both are set to 0, the frequency jump function
is disabled. The principle of the jump frequencies and jump amplitude is shown in the
IROORZLQJ¿JXUH
)LJXUH3ULQFLSOHRIWKHMXPSIUHTXHQFLHVDQGMXPSDPSOLWXGH
Output
frequency (Hz)
Jump
frequency 2
Jump
frequency 1
Time (t)
)UHTXHQF\MXPSDPSOLWXGH
)UHTXHQF\MXPSDPSOLWXGH
)UHTXHQF\MXPSDPSOLWXGH
)UHTXHQF\MXPSDPSOLWXGH