MD380 User Manual Desc
ription of Function Codes
- 235 -
)unction Code Name Setting Range Default
A6-09
Corresponding setting of A
I
curve 5 minimum input
-100.0%–100.0% 0.0%
A6-10 AI curve 5 inÀexion 1 input A6-08 to A
6-12 3.00 V
A6-11
Corresponding setting of A
I
curve 5 inÀexion 1 input
-100.0%–100.0% 30.0%
A6-12 AI curve 5 inÀexion 1 input A6-10 to A
6-14 6.00 V
A6-13
Corresponding setting of A
I
curve 5 inÀexion 1 input
-100.0%–100.0% 60.0%
A6-14 AI curve 5 maximum input A6-14 to 10.00 V 10.00 V
A6-15
Corresponding setting of A
I
curve 5 maximum input
-100.0%–100.0% 100.0%
The function of curve 4 and curve 5 is similar to that curve 1 to curve 3, but curve 1 to
FXUYHDUHOLQHVDQGFXUYHDQGFXUYHDUHSRLQWFXUYHVLPSOHPHQWLQJPRUHÀH[LEOH
corresponding relationship. The schematic diagram of curve 4 and curve 5 is shown in the
IROORZLQJ¿JXUH
)LJXUH6FKHPDWLFGLDJUDPFXUYHDQGFXUYH
AI corresponding setting
Corresponding setting
of AI max. input
Corresponding setting of
AI curve inflexion 1 input
0 V (0 mA)
Corresponding setting of
AI curve inflexion 2 input
Corresponding setting
of AI min. input
AI curve
inflexion 1
AI curve
inflexion 2
AI input
voltage
10 V (20 mA)
:KHQVHWWLQJFXUYHDQGFXUYHQRWHWKDWWKHFXUYHVPLQLPXPLQSXWYROWDJHLQÀH[LRQ
YROWDJHLQÀH[LRQYROWDJHDQGPD[LPXPYROWDJHPXVWEHLQLQFUHPHQWRUGHU
)$,FXUYHVHOHFWLRQLVXVHGWRVHOHFWFXUYHIRU$,WR$,
)unction Code Parameter Name Setting Range Default
A6-16
Jump point of A
I1 input
corresponding setting
-100.0%–100.0% 0.0%
A6-17
Jump amplitude of AI1 input
corresponding setting
0.0%–100.0% 0.5%
A6-18
Jump point of A
I2 input
corresponding setting
-100.0%–100.0% 0.0%
A6-19
Jump amplitude of A
I2 input
corresponding setting
0.0%–100.0% 0.5%