MD380 User Manual Operation, Display and Application Example
- 59 -
4.7.5 JOG Running
In certain applications, the AC drive needs to run in low speed temporarily to facilitate
equipment test or other commissioning operations. In this case, you can set the AC drive to
perform JOG running.
)LJXUH-2*UXQQLQJ
JOG acceleration
time ()8- 0 1)
Time (t)
Output
frequency
Acceleration/Deceleration
base frequency ()0-25)
Set
acceleration time
Set
deceleration time
Actual
acceleration time
Actual
deceleration time
JOG deceleration
time ()8-02)
JOG running
frequency ()0-08)
JOG
command
Ƶ
Parameter Setting and Operation of JOG Running in Operation Panel Control
)LJXUH-2*UXQQLQJLQRSHUDWLRQSDQHOFRQWURO
JOG
command key
0).K
)7-01 = 3 )0-02 = 0
)8-00 (
JOG running frequency)
)8-01 (
JOG acceleration time)
)8-02 (
JOG deceleration time)
Operation
panel control
'HILQHWKH0).K key
as the ")RUZDUG
JOG" key
)RUZDUG
JOG
(stop state)
JOG running
parameters
6HWWKHSDUDPHWHUVDFFRUGLQJWRWKHSUHFHGLQJ¿JXUH,QVWRSVWDWHRIWKH$&GULYHKROG
down
MF.K
, and the AC drive starts JOG running. After you release
MF.K
, the AC drive
decelerates to stop.
7RSHUIRUPUHYHUVH-2*VHW)WRDQG)WR+ROGGRZQ
MF.K
and the AC
drive starts reverse JOG running.