Figure 5‑38 AC output reactor model
Note
The following recommended AC output reactors are applicable only to T1 to T9
models.
For T10 to T12 models, if AC output reactors are required, purchase the AC output
reactors with the model name containing "‑L".
The T13 model is equipped with a built‑in output reactor as standard.
Table 5–46 Selection of Inovance AC output reactors (three‑phase 380 V to 480 V)
Structure Drive Model Reactor Model Inductance (mH) Loss (W)
T1 MD520‑4T0.4B(S) MD‑OCL‑5‑1.4‑4T‑1% 1.4
MD520‑4T0.7B(S) MD‑OCL‑5‑1.4‑4T‑1% 1.4
MD520‑4T1.1B(S) MD‑OCL‑5‑1.4‑4T‑1% 1.4
MD520‑4T1.5B(S) MD‑OCL‑5‑1.4‑4T‑1% 1.4
MD520‑4T2.2B(S) MD‑OCL‑7‑1.0‑4T‑1% 1.0
MD520‑4T3.0B(S) MD‑OCL‑10‑0.7‑4T‑1% 0.7
T2 MD520‑4T3.7B(S) MD‑OCL‑10‑0.7‑4T‑1% 0.7
MD520‑4T5.5B(S) MD‑OCL‑15‑0.47‑4T‑1% 0.47
T3 MD520‑4T7.5B(S) MD‑OCL‑20‑0.35‑4T‑1% 0.35
MD520‑4T11B(S) MD‑OCL‑30‑0.23‑4T‑1% 0.23
T4 MD520‑4T15B(S) MD‑OCL‑40‑0.18‑4T‑1% 0.18
T5 MD520‑4T18.5(B)(S)
MD520‑4T18.5(B)(S)‑T
MD‑OCL‑40‑0.18‑4T‑1% 0.18
MD520‑4T22(B)(S)
MD520‑4T22(B)(S)‑T
MD‑OCL‑50‑0.14‑4T‑1% 0.14
T6 MD520‑4T30(B) (S) MD‑OCL‑60‑0.12‑4T‑1% 0.12
MD520‑4T37(B) (S) MD‑OCL‑80‑0.087‑4T‑1% 0.087
T7 MD520‑4T45(B) (S) MD‑OCL‑90‑0.078‑4T‑1% 0.078
MD520‑4T55(B) (S) MD‑OCL‑120‑0.058‑4T‑1% 0.058