Technical Data
152
Three-phase 200 V to 240 V
Table 6–8 Electrical parameters of T1 to T2 models (three‑phase 200 V to 240 V)
Item
Specification
Module: MD520‑2Txxxxx
0.4B(S) 0.7B(S) 1.1B(S) 1.5B(S) 2.2B(S) 3.7B(S)
Structure T1 T2
Output Power (kW) (heavy load)
0.4 0.75 1.1 1.5 2.2 3.7
Power (kW) (light load)
0.75 1.1 1.5 2.2 3.7 5.5
Rated output current (A)
(heavy load)
2.1 3.8 5.1 7.2 9 13
Rated output current (A)
(light load)
3.8 5.1 7.2 9 13 17
Output voltage Three‑phase 0 V to input voltage
Maximum output
frequency
599 Hz (edited through parameters)
Carrier frequency
0.5 kHz to 16.0 kHz (automatically adjusted according to the load
characteristics)
Overload capacity
Heavy load: 60s at 150% of the rated current
Light load: 60s at 110% of the rated current
Input Rated input current (A)
(heavy load)
2.4 4.6 6.3 9 11.4 16.7
Rated input current (A)
(light load)
3.7 6.4 9.1 11.3 15.9 22.4
Rated voltage and
frequency
Three‑phase 200 V to 240 V, 50/60 Hz
Allowable voltage
fluctuation range
‑15% to +10%, or 170 VAC to 264 VAC
Allowable frequency
fluctuation range
±5%, or 47.5 Hz to 63 Hz
Power supply capacity
(kVA) (heavy load)
1.1 2.1 2.9 4.1 5.2 7.6
Power capacity (kVA) (light
load)
2.1 2.9 4.1 5.2 7.6 14.7
Heat dissipation
design
Thermal design power (kW)
(heavy load)
0.046 0.068 0.081 0.109 0.138 0.201
Thermal design power (kW)
(light load)
0.068 0.081 0.109 0.138 0.201 0.355
Exhaust air volume (CFM)
9 9 9 20 24
Overvoltage
class
OVCIII
Pollution degree
PD2
IP rating
IP20