Technical Data
‑153‑
Table 6–9 Electrical parameters of T3 to T6 models (three‑phase 200 V to 240 V)
Item
Specification
Module: MD520‑2Txxxxx
5.5B(S) 7.5B(S) 11(B)(S) 15(B)(S) 18.5(B)(S)
Structure T3 T4 T5 T6
Output Power (kW) (heavy load)
5.5 7.5 11 15 18.5
Power (kW) (light load)
7.5 11 15 18.5 22
Rated output current (A)
(heavy load)
25 32 45 60 75
Rated output current (A) (light
load)
32 45 60 75 91
Output voltage Three‑phase 0 V to input voltage
Maximum output frequency 599 Hz (edited through parameters)
Carrier frequency
0.5 kHz to 16.0 kHz (automatically adjusted according to the load
characteristics)
Overload capacity
Heavy load: 60s at 150% of the rated current
Light load: 60s at 110% of the rated current
Input Rated input current (A) (heavy
load)
32.2 41.3 59 57 69
Rated input current (A) (light
load)
39.7 44 65.8 71 86
Rated voltage and frequency Three‑phase 200 V to 240 V, 50/60 Hz
Allowable voltage fluctuation
range
‑15% to +10%, or 170 VAC to 264 VAC
Allowable frequency
fluctuation range
±5%, or 47.5 Hz to 63 Hz
Power supply capacity (kVA)
(heavy load)
14.7 18.9 27 26.1 31.6
Power supply capacity (kVA)
(light load)
18.9 27 26.1 31.6 40.7
Heat
Dissipation
Design
Thermal design power (kW)
(heavy load)
0.355 0.454 0.551 0.694 0.815
Thermal design power (kW)
(light load)
0.454 0.551 0.694 0.815 1.01
Exhaust air volume (CFM)
40 42 57.4 118.5 118.5
Overvoltage
class
OVCIII
Pollution
degree
PD2
IP rating
IP20