Technical Data
‑156‑
Single-phase 200 V to 240 V
Table 6–12 Electrical parameters of T2 models (single‑phase 200 V to 240 V)
Item
Specification
Module: MD520‑2Sxxxxx
0.4B(S) 0.7B(S) 1.5B(S) 2.2B(S)
Structure T2
Output Power (kW) (heavy load)
0.4 0.75 1.5 2.2
Rated output current (A)
(heavy load)
2.3 4 7 9.6
Output voltage Three‑phase 0 V to 240 V (subject to input voltage)
Maximum output
frequency
599 Hz (edited through parameters)
Carrier frequency
0.5 kHz to 16.0 kHz (automatically adjusted according to the load
characteristics)
Overload capacity
Heavy load: 60s at 150% of the rated current
Light load: 60s at 110% of the rated current
Input Rated input current (A)
(heavy load)
5.4 8.2 14 20
Rated voltage and
frequency
Single‑phase 200 V to 240 V, 50/60 Hz
Allowable voltage
fluctuation range
‑15% to +10%, or 170 VAC to 264 VAC
Allowable frequency
fluctuation range
±5%, or 47.5 Hz to 63 Hz
Power supply capacity
(kVA) (heavy load)
1.4 2.2 3.7 6
Heat dissipation
design
Thermal design power
(kW) (heavy load)
0.043 0.065 0.097 0.121
Exhaust air volume (CFM)
20 20 20 20
Overvoltage class
OVCIII
Pollution degree
PD2
IP rating IP20 (open type, for IEC products)
Type 1 (enclosed type, for UL‑certified products)