General Safety Instructions
Dynamic braking is common in rotating mechanical structures. For example, when
a motor has stopped running, it keeps rotating due to the inertia of its load. In this
case, this motor is in the regenerative state and short‑circuit current passes
through the dynamic brake. If this situation continues, the drive, and even the
motor, may be burned.
Safety Label
For safe equipment operation and maintenance, comply with the safety labels on the
equipment. Do not damage or remove the safety labels. See the following table for
descriptions of the safety labels.
Safety Label Description
Never fail to connect Protective Earth (PE) terminal. Read the manual
and follow the safety instructions before use.
Do not touch terminals within 15 minutes after Disconnect the
power. Risk of electric shock.
Do not touch heatsink when power is ON. Risk of burn.