Keypad
62
For example, if H02.32 is set to 00 and the motor speed is not 0 rpm, the keypad
displays the value of H0b.00.
The following table describes the monitoring parameters in H0b.00.
Param. No. Name Unit
Meaning
Example of Display
H0b.00
Motor speed
actual value
rpm
Displays the actual
value of the motor
speed after round‑off,
which can be accurate
to 1rpm.
3000 rpm:
‑3000 rpm:
5.3 Parameter Settings
Example of parameter settings
You can set parameters through the keypad. For details on parameters, see Chapter
"List of Parameters". The following figure shows how to switch from position control
mode to speed control mode using the keypad after power‑on.
Figure 5‑5 Example of parameter setting
MODE: Used to switch the keypad display mode and return to the previous
interface.
UP/DOWN: Used to increase or decrease the value of the blinking digit.
SHIFT: Used to shift the blinking digit.
SET: Used to save the present setpoint or switch to the next interface.