EasyManua.ls Logo

Inovance SV660F Series - Fault Reset Procedures; Operating Procedure for Fault Reset

Inovance SV660F Series
97 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
General
‑13‑
EC directives and standards
Low Voltage Directive 2014/35/EU Standard EN 61800‑5‑1
EMC Directive 2014/30/EU Standard IEC 61800‑3:2017 IEC61800‑5‑2:2016
Machinery Directive 2006/42/EC (Safety Functions) Standard IEC 61800‑5‑2
Safety standard
Model
Safety standard
Reference
SV660XXXX
Functional safety
IEC 61508: 2010
ISO 13849‑1: 2015
ISO 13849‑2: 2012
IEC 62061: 2021
IEC 61800‑3: 2017
EN 61508: 2010
EN ISO 13849‑1: 2015
EN ISO 13849‑2: 2012
EN IEC 62061: 2021
EN IEC 61800‑3: 2018
IEC60204‑1:2016 (in extracts)
EN60204‑1:2018 (in extracts)
EMC
IEC 61800‑5‑2: 2016
IEC 61800‑3:2017
IEC 61326‑3‑1:2017
IEC 61000‑6‑7:2014
EN 61800‑5‑2: 2017
EN IEC 61800‑3:2018
EN 61326‑3‑1:2017I
LVD
IEC 61800‑5‑1:2016
EN 61800‑5‑1:2007+A1: 2017 (in extracts)
Safety data
Item
Safety data
SIL
SIL3, IEC61508
Maximum SIL3, EN IEC62061
PFH
D
PFH
D
≤0.16×10
‑7
[1/h]
(16% of SIL3)
Cat.
3, EN ISO 13849‑1
PL
e, EN ISO 13849‑1
MTTFd
441.3 years (high)
DCavg
≥90% (medium)
T
1
10 years
HFT 1
SC SC3
λ
S
1.49×10
‑7
/ h
λ
DD
1.32×10
‑8
/ h

Other manuals for Inovance SV660F Series

Related product manuals