General
‑15‑
Item
Description
Shock resistance
Item
Test Condition
Test reference See IEC 60068‑2‑27: 2008 Table 17
Condition
EUT powered on, operating normally
Motion mode
Half‑sine pulse
Shock amplitude/
Time
50 m/s
2
(5 g) 30 ms
Number of shocks
3 per axis on each of three mutually
perpendicular axes
Axes
±X, ±Y, ±Z
Detail of mounting According to manufacturer's specification
IP rating
IP20
Pollution degree
(PD)
PD2: free of corrosive or explosive gases; free of exposure to water,
oil or chemicals; free of dust, salts or iron dust
Altitude 2000 m or below
Cooling method Dry clean air (natural convection)
Others
Free of static electricity, strong electromagnetic fields, magnetic
fields, or exposure to radioactivity
● The drive complies with EMC standards EN/IEC 61800‑3:2017, IEC 61326‑3‑1, and
IEC 61800‑5‑2
● Others
Item
Description
Applicable servo
drives
SV660FS1R6I‑FS
SV660FS2R8I‑FS
SV660FS5R5I‑FS
SV660FS7R6I‑FS
SV660FS012I‑FS
SV660FT3R5I‑FS
SV660FT5R4I‑FS
SV660FT8R4I‑FS
SV660FT012I‑FS
SV660FT017I‑FS
SV660FT021I‑FS
SV660FT026I‑FS
Position
Integrated on the control board of the drive
Safety function ‑
Inputs
Two channels: STO1/STO2
The STO subsystem elements must always be able to operate within the range of
temperature, humidity, corrosion, dust, and vibration and other requirements
specified above.