EasyManua.ls Logo

Inovance SV660F Series - Description of Fault Codes; Solutions to Common Faults

Inovance SV660F Series
97 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Product Information
‑27‑
No. Name
Description
L1, L2, L3 (main
circuit power input
terminals)
Used as the power input terminals for a three‑phase 220
V servo drive. See the nameplate for the rated voltage
class.
P⊕, D, C (terminals
for connecting
external
regenerative
resistor)
Remove the jumper bar between terminals P⊕ and D
before connecting an external regenerative resistor
between terminals P⊕ and C.
P⊕, N⊖ (servo bus
terminals)
Used by the common DC bus for multiple servo drives.
U, V, W (terminals
for connecting the
servo motor)
Connected to U, V, and W phases of the servo motor.
Motor grounding
terminal
Connected to the grounding terminal of the motor for
grounding purpose.
Battery location Used to hold the battery box of the absolute encoder.
CN3, CN4 (Profinet
communication
terminal)
CN4(P1) is connected to the host controller, and CN3(P2)
is connected to a slave.
CN6 (STO safety
function terminal)
Connected to external functional safety signal for
functional safety purpose.
CN5
(communication
terminals)
Connected to RS‑232 communication instruction device.
CN1 (control
terminal)
Used by reference input signals and other I/O signals.
CN2 (terminal for
connecting the
encoder)
Connected to the motor encoder terminal.
Servo drive
grounding terminal
Connected to the grounding terminal of the power supply
for grounding purpose
Note
The main circuits of models S7R6 and S012 can be connected to a single‑phase or a three‑
phase power supply, depending on which one is available on site. No derating is required
when a single‑phase power supply is used for models S7R6 and S012.