Intel® Server S2600WF Product Family Configuration Guide
99
4.7.1.2 Drive Bay Module # 1 – NVMe* Cable Guide
The following table identifies the appropriate PCIe NVMe data cable kit(s) necessary to route PCIe signals from any of the onboard PCIe OCuLink
connectors and / or PCIe switch add-in card options to the 8x2.5” combo backplane installed to Drive Bay Module #1.
Select the cable kit or kits required to support the specific PCIe source or sources and the appropriate number of NVMe drives being installed to Drive
Bay Module #1 only.
Note: CR and CV refer to the connector types at each end of the PCIe OCuLink cable. See Table 51
.
Table 60. Drive bay module #1 NVMe* cable guide
System
Configuration
Support
Drive Bay Module (BP) #1
PCIe Switch Card
Option on Riser #1
PCIe Switch Card
Option on Riser #2
Option on Riser #3
1
Drive Bay Module (BP) #1
Cable
Routing
Drive Bay #1
R2208WF
R2208WF +8
R2224WF
Up to Eight
2.5” NVMe
SSDs
PCIe SSD 0 (CR) BP 0 (CV)
470mm - AXXCBL470CVCR
PCIe SSD 1 (CR) BP 1 (CV)
530mm – AXXCBL530CVCR
PCIe SSD 2 (CR) BP 2 (CV)
700mm – AXXCBL700CVCR
PCIe SSD 3 (CR) BP 3 (CV)
700mm – AXXCBL700CVCR
PCIe SSD 0 (CR) BP 4 (CV)
700mm – AXXCBL700CVCR
PCIe SSD 1 (CR) BP 5 (CV)
700mm – AXXCBL700CVCR
PCIe SSD 2 (CR) BP 6 (CV)
700mm – AXXCBL700CVCR
PCIe SSD 3 (CR) BP 7 (CV)
700mm – AXXCBL700CVCR
All cables routed left
Add-in Card
AXXP3SWX08040
or
Switch BP ports 4-7
Left
Add-in Card
AXXP3SWX08040
or
Switch BP ports 4-7
Left
Add-in Card
AXXP3SWX08040
or
Switch BP ports 4-7
Left
8-port PCIe Switch
Add-in Card
AXXP3SWX08080
any open PCIe slot
Cable 1
Switch BP ports 4-7
Cable 2
A2U8PSWCXCXK1
Left
Left
8-port PCIe Switch
Add-in Card
AXXP3SWX08080
any open PCIe slot
Cable 1
Switch BP ports 4-7
Cable 2
Left
Left
8-port PCIe Switch
Add-in Card
AXXP3SWX08080
PCIe slot #2
Cable 1
Switch BP ports 4-7
Cable 2
Left
Left
1
PCIe switch cards installed to Riser #3 cannot be supported at this time.