Intel® Server Board S2600CO Family TPS Appendix C: Integrated BMC Sensor Tables
Revision 1.0
Intel order number G42278-002
123
Rearm Sensors
The rearm is a request for the event status for a sensor to be rechecked and updated
upon a transition between good and bad states. Rearming the sensors can be done
manually or automatically. This column indicates the type supported by the sensor. The
following abbreviations are used to describe a sensor:
o A: Auto-rearm
o M: Manual rearm
Default Hysteresis
The hysteresis setting applies to all thresholds of the sensor. This column provides the
count of hysteresis for the sensor, which can be 1 or 2 (positive or negative hysteresis).
Criticality
Criticality is a classification of the severity and nature of the condition. It also controls the
behavior of the Control Panel Status LED.
Standby
Some sensors operate on standby power. These sensors may be accessed and/or
generate events when the main (system) power is off, but AC power is present.
Note: All sensors listed below may not be present on all platforms. Please check platform EPS
section for platform applicability and platform chassis section for chassis specific sensors.
Redundancy sensors will be only present on systems with appropriate hardware to support
redundancy (for instance, fan or power supply).