Appendix C: Integrated BMC Sensor Tables Intel® Server Board S2600CO Family TPS
Revision 1.0
Intel order number G42278-002
132
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event /
Reading
Type
Event Offset Triggers
Contrib. To
System Status
Assert
/ De-
assert
Readable
Value /
Offsets
Event
Data
Rearm
Stand-
by
Processor 1 DIMM
Thermal Trip
(P1 Mem Thrm Trip)
C0h
All
Temperature
01h
Digital
Discrete
03h
01 State Asserted
Fatal
As
and
De
Trig Offset
M
X
Processor 2 DIMM
Thermal Trip
(P2 Mem Thrm Trip)
C1h
All
Temperature
01h
Digital
Discrete
03h
01 State Asserted
Fatal
As
and
De
Trig Offset
M
X
Global Aggregate
Temperature Margin 1
(Agg Therm Mrgn 1)
C8h
Platform
Specific
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Global Aggregate
Temperature Margin 2
(Agg Therm Mrgn 2)
C9h
Platform
Specific
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Global Aggregate
Temperature Margin 3
(Agg Therm Mrgn 3)
CAh
Platform
Specific
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Global Aggregate
Temperature Margin 4
(Agg Therm Mrgn 4)
CBh
Platform
Specific
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Global Aggregate
Temperature Margin 5
(Agg Therm Mrgn 5)
CCh
Platform
Specific
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Global Aggregate
Temperature Margin 6
(Agg Therm Mrgn 6)
CDh
Platform
Specific
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Global Aggregate
Temperature Margin 7
(Agg Therm Mrgn 7)
CEh
Platform
Specific
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Global Aggregate
Temperature Margin 8
(Agg Therm Mrgn 8)
CFh
Platform
Specific
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Baseboard +12V
(BB +12.0V)
D0h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog
R, T
A
Baseboard +5V
(BB +5.0V)
D1h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog
R, T
A