Appendix C: Integrated BMC Sensor Tables Intel® Server Board S2600CO Family TPS
Revision 1.4
Intel order number G42278-004
132
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/
Reading
Type
Event Offset Triggers Contrib. To
System Status
Assert/
De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Baseboard CMOS Battery
(BB +3.3V Vbat)
DEh All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog R, T A
Baseboard +1.35V P1 Low
Voltage Memory AB VDDQ
(BB +1.35 P1LV AB)
E4h All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog R, T A
Baseboard +1.35V P1 Low
Voltage Memory CD VDDQ
(BB +1.35 P1LV CD)
E5h All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog R, T A
Baseboard +1.35V P2 Low
Voltage Memory AB VDDQ
(BB +1.35 P2LV AB)
E6h All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog R, T A
Baseboard +1.35V P2 Low
Voltage Memory CD VDDQ
(BB +1.35 P2LV CD)
E7h All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog R, T A
Baseboard +3.3V Riser 1
Power Good
(BB +3.3 RSR1 PGD)
EAh
Platform
Specific
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog R, T A
Baseboard +3.3V Riser 2
Power Good
(BB +3.3 RSR2 PGD)
EBh
Platform
Specific
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog R, T A
Hard Disk Drive 1 -15 Status
(HDD 1 - 15 Status)
F0h
-
FEh
Chassis-
specific
Drive Slot
0Dh
Sensor
Specific
6Fh
00 - Drive Presence OK
As
and
De
– Trig Offset A X
01- Drive Fault Degraded
07 - Rebuild/Remap in
progress
Degraded
Notes:
1. Redundancy sensors will be only present on systems with appropriate hardware to support redundancy (for instance, fan or power supply).
2. This is only applicable when the system does not support redundant fans. When fan redundancy is supported, then the contribution to system state is driven by the fan
redundancy sensor.