Enter + 3902 + XX + Enter, where XX goes from 01 to 64
3902 Zone 01 to 64
Key 1
Timed Zone
Key 2
Follower Zone
Key 3
24h Zone
Key 4
Panic Zone
Key 5
Medical Emergency Zone
Key
6
Fire Zone
Key
7
Electric fence trigger (only available as of version 2.0)
Key
8
Doorbell ringing (available only as of version 2.0)
Note: each zone can have permission on only one attribute. If you check the permis-
sion on more than one attribute, the rst one checked is the one that counts.
3.8. Power-on input (as of version 2.00)
Power-On input zone:
Enter + 09 + Zone (2 digits) + Enter
Power-On input partition:
Enter + 516 + Enter
Key
5
Partition A
Key
6
Partition B
Key
7
Partition C
Key
8
Partition D
Permission to activate and/or deactivate the power-on input:
Enter + 518 + Enter
Key
2
Permission to activate
Key
3
Permission to deactivate
3.9. Open XEZs zones after bus failure (as of version 3.80)
To enable:
Enter + 518 + enter
Key
4
Opens the zones on failure
Note: as of version 5.0 the Open Zones on Failure function will leave enabled from
the factory.