25
2 = panic with siren
3 = silent panic
4 = re
?? = user 01 to 16
Remote control for PGM
Enter + 66 + ?? + Enter + control activation
?? (01 to 19) = PGM1 to PGM19
Delete wireless PGM
Enter + 76 + ?? + Enter
?? (01 to 19) = PGM1 to PGM19
3.17. Wireless sensors
We do not guarantee the registration/functionality of our centers with wireless sen-
sors that are not manufactured by Intelbras.
Enter + 61 + ?? + Enter + activate wireless sensor
?? = zone number 17 to 64
To delete wireless sensors
Enter + 71 + ?? + Enter = deletes wireless sensor
?? = zone number 17 to 64
Sensor Test
Enter + 52 + Enter
Wireless sensors battery test
Enter + 79 + Enter
Bus devices test
Enter + 59 + ? + Enter
? = function group 0 and 1
3.18. Resetting wireless devices
Enter + 7 + Cancel + Enter
Note: this command deletes all programmed wireless devices.