18
Calendar Programming
Enter + 401 + DD + MM + AA + Enter
DD = two-digit day
MM = two-digit month
AA = two-digit year
Enable the siren beep on activation/deactivation
Enter + 510 + Enter + select the 3 key + Enter
Enable siren beep on activation/deactivation from the remote control
Enter + 51 + 6 + Enter + select option 3 + Enter
Enable siren beep on activation/deactivation from the keyboard
Enter + 51 + 6 + Enter + select option 4 + Enter
Programming of siren time
Enter + 41 + ?? + Enter ?? = 01 to 99 minutos
If ?? = 00, siren time = 15 minutes
Time to Send AC Failure
Enter + 48 + ?? + Enter
?? = 01 to 99 minutos
3.12. Auto activation
(Programming only by the installer)
Programming auto activation when idle
Note:
as of version 2.30, auto activation when idle will be usable together with scheduled
auto activation.
Enter + 460 + ?? + Enter
?? = idle time from 00 to 99 minutes
Programming of auto activation by time
Note: As of version 2.30, the time-based auto activation will be disabled. To use auto
activation at a specic time, use scheduled auto activation.
Enter + 461 + HHMM + Enter
HHMM = auto activation time with 4 digits in 24h format
To cancel the auto activation by time, type:
Enter + 461 + 0000 + Enter