14
Note:
The zones that can be congured with this function are 17 to 64. And they can
be programmed as shown in the table below:
Enter + 78 + G + Enter
G = 0 Not applicable
1 Not applicable
2 Zones 17 to 24
3 25 to 32
4 33 to 40
5 41 to 48
6 49 to 54
7 55 to 64
Smart Zone Time
Enter + 49 + ??? + Enter
??? = 001 to 030 seconds
Automatic zone cancellation
Enter + 53 + ? + Enter
? = number of triggers to cancel from 0 to 9
Automatic zone cancellation by zone opening
Enter + 51 + 1 + Enter + select the 8 key + Enter
3.6. Partitioning
Enable Partitioning
Enter + 510 + Enter + Key 1 + Enter
Use the keyboard to select option 1 (remain lled) to enable partitioning. If it is left
empty, partitioning will be disabled (factory default).
Select the zones for the partitions
Enter + 0 + P + G + Enter
P = Partitions 1 to 4, where 1 = partition A / 2 = partition B / 3 = partition C / 4 =
partition D
G = zone group 0 to 7, where 0 = zones 1 to 8, 1 = 9 to 16, 2 = 17 to 24, 3 = 25 to
32, 4 = 33 to 40, 5 = 41 to 48, 6 = 49 to 56, and 7 = 57 to 64.