Intercall 600/700 Installation & Operation Guide Issue 4.27 Page 26 of 78
Installation Procedures – DPU414 connected to L747.
The L747 has now taken over from the L607 and L707 printer interface. It is plug and play and detects which system it
is connected to. Please follow the instructions below:
• Unpack the Equipment and check you have the following items:
• DPU414 Thermal Printer
• L747 Universal Interface
• Mains ‘plug top style’ Power supply (PSU)
• Parallel Data Lead for connection between L747 & Printer
• Check battery is fitted into printer (See DPU414 Operation Manual page 25)
• Roll of thermal paper
• Locate DPU414 as required within 1.5 metres of L747 and mains socket.
• Plug power supply into printer & 13 amp socket
(See DPU414 manual page 12)
• Switch power supply and printer on
(See DPU414 manual page 10)
• Install paper roll into printer
(See DPU414 manual page 13 & 14)
• Set ALL 8 of the L747 DIP switches to the OFF position
(See Below).
• Set the JP1 and JP2 jumpers on the L747 on one pin only.
• Connect parallel data cable between L747 and Printer.
(Manual page 21)
• Ensure DPU414 ‘power’ and ‘on line’ lamps are lit green.
(Manual page 10)
• Connect the L747 to the NETWORK + and – cables. OBSERVE POLARITY !
• After about 5 to 10 seconds the printer will print the start up and the L747 LED will flash red once per second.
• Check time is correct. Should you need to advance or retard the hour for BST or GMT, Press and hold the
BST/GMT button until the red LED stops flashing and the printer reports the hour has been advanced or
retarded. (If you go over repeat the operation until the correct hour is shown)
• The date and time is factory programmed, this can be altered using the ‘747set.exe’ software utility, a copy of
which can be downloaded from the Intercall web site.
• Secure the L747 to the wall in the backbox.
(See Below).
• Secure the Parallel data cable with the jack screws.
(See Below).
• Download system text in the normal way.
(See Below).
• Changing the position of DIL Switch 2 will make the printer print out all text stored in the system (Addresses and
User ID) and it will show a large dot to the left of all addresses that have a call point connected. – Ideal for
commissioning and double address testing.
• The red LED on the front of the L747 flashes once per second when receiving good data from the network. If the
printer is switched off, set off line or not connected – the red LED will stop flashing. If the printer runs out of
paper – The data will be stored and printed out when the new paper roll is fitted.
• The following switches can be set on the L747 to select which calls printed etc – please check with the client.
SW1 OFF – Print when a fault occurs (Unit failure/tamper/mains failure) (No audible alarm)
SW1 ON – Don’t print when a faults occurs. (No audible alarm)
SW3 OFF – Intercall mode (Prints Nurse Present).
SW3 ON – Guardian Visit mode (Prints ‘Visit’ if reset trigger button pressed)
SW4 OFF – Print in condensed mode for Intercall 700 (Small Characters on one line)
SW4 ON – Print in normal mode for Intercall 700 (Larger characters on two lines)