SCP Slave Call Point.
Slave call points are used to cover several beds or areas in one room or ward where each individual point does not
required a separate identity on the call system. Units must be wired back to a standard call point to provide the reset and
to generate the call address. Slave Call Points can only generate ‘standard patient call’ from either the call button or
pear lead socket.
Pear lead Socket: Industry standard socket that will accept any normally open switch.
This socket can accept input from pear leads, pressure mats, radio triggers etc.
Installation: Flush or surface mount in standard ‘single size’ electrical backbox.
Size & Weights: 80 x 80 x 40 mm, 60g
Intercall 600
9
Intercall 700
9
Above: Front panel and pcb detail of the SCP Slave Call Point
SCP Connects to call point ‘X’ and ‘-‘ terminals (L722 call point shown above)
Several Slave Call Points may be used to trigger a single call point