32 NX-595E Installation Manual
Activation Event: Select the required event from the drop down list that will
activate the corresponding relay
Activation Time: Time the relay will be active, options 0 –255
Minutes: On if output should be timed in minutes; off if timed in seconds
Latch: On if output should latch; off if output should be timed.
Code Reset: On if output should stop timing upon code entry; off if output should
follow timer.
Open Schedule: On if output should only activate between the opening and
closing time
Close Schedule: On if output should only activate between the closing and
opening time
Invert: On if output should be inverted
Activation Partitions: Is used to select the partition(s) the event must occur in
before the output will activate.
Schedule Times: Sets the Opening / Closing hours and minutes (24 hour
format) and the days of the week the event must occur in before the output will
activate.