12
Version 1.0 (11/2007) en
Original language
Product information
RollerDrive EC200
Speed settings
If you do not use the recommended DriveControl (see "DriveControls for the 
RollerDrive EC200", page 10), you may change the speed of the RollerDrive 
EC200 by altering the voltage on pin 5 of the motor plug.
Input voltage of Pin 5 at motor plug is not polarity-
proof
Damage to the RollerDrive
¾ Ensure the correct polarity.
$QDORJYROWDJHVHWWLQJRQSLQRIPRWRUSOXJ>9'&@
6SHHG3HUFHQWDJH>@
Hint
In the hatched area the RollerDrive does not run within the specified tolerance of 
±5%.
Rotary switch 
speed setting at 
DriveControl
Voltage setting 
on pin 5 
[VDC]
Speed of transport [m/s (ft/min)] ± 5 %
Gear ratio 
12:1
Gear ratio 
16:1
Gear ratio 
36:1
Gear ratio 
48:1
Gear ratio 
64:1
0/8
5 to 24
0.98 (192.7) 0.74 (145.6) 0.33 (64.2) 0.25 (49.2) 0.18 (36.1)
1/9 0.98 (192.7) 0.74 (145.6) 0.33 (64.2) 0.25 (49.2) 0.18 (36.1)
2/A 4 0.75 (147.2) 0.56 (110.4) 0.25 (49.1) 0.19 (36.8) 0.14 (27.6)
3/B 3.75 0.56 (110.4) 0.42 (82.8) 0.19 (36.8) 0.14 (27.6) 0.11 (20.7)
4/C 3.30 0.41 (80.1) 0.31 (60.1) 0.14 (26.7) 0.10 (20.0) 0.08 (15.0)
5/D 2.93 0.30 (58.5) 0.22 (43.8) 0.10 (19.5) 0.07 (14.6) 0.06 (11.0)
6/E 2.68 0.21 (41.1) 0.16 (30.9) 0.07 (13.7) 0.05 (10.3) 0.04 (7.7)
7/F 2.44 0.14 (28.1) 0.11 (21.1) 0.05 (9.4) 0.04 (7.0) 0.03 (5.3)