Invacare®TDX®SP2Series
Theoperatinghourcounterislocatedonrearshroud(2).
Removingoperatinghourscounter
1.Switchcontrolssystemofwheelchairoff.
2.Removerearshroudasdescribedinchapter“Shrouds” .
3.
Loosenandremovenut(5)includinglockingwasher(4)
using10mmsocketwrench.
4.Pullmountingbracket(2)offofthreadedrod(3).
5.Removeretainingframe(6).
6.Pulloperatinghourscounterforwardsoutofrearshroud.
7.Disconnecttwoplugsofcable(notshowninthe
illustration)frompins(-)&(+).
8.Replaceoperatinghourcounterandcablerespectively.
Installingoperatinghourcounter
Riskofdamage
Ifcounteriswronglyconnected.Ifplusandminus
wiresareconnectedwrongway,itwilldamage
electroniccomponentsofoperatinghourcounter .
–Makesurecableisconnectedcorrectly.
1.Connectplugonbluewire(-)topinonoperatinghour
counterwhichismarkedwitha“minus”symbol.
Thebrownwireisadditionallymarkedwithyellow
sleevewith“plus”symbolonit.
2.Insertcablefromoutsidethroughcut-outforoperating
hourcounterlocatedinrear.
3.Positionoperatinghourcounterincut-out.
4.
5.Repositionretainingframe(6).
6.Placemountingbracket(2)onthreadedrod(3)sothat
mountingbracketpressesretainingframeonshroud.
7.Placelockingwasher(4)andnut(5)onthreadedrod.
8.Tightennuthand-tight.
9.Installrearshroudagain.Seechapter6.6Shrouds,page
30.
6.7.4Updatingdrivingprogram
CAUTION!
Everyalterationtothedriveprogramcan
inuencehandlingandtippingstabilityof
mobilitydevice.
–Alterationstodriveprogrammustonlybe
carriedoutbytrainedInvacare®providers.
–Invacare®canonlyassumeawarrantyforsafe
handlingofmobilitydevice–inparticular
tippingstability-forunalteredstandarddrive
programs.
6.7.5Makingbatteriesaccessible
Thischapterappliesformobilitydeviceswithout
poweredsimpletilt20°.Formobilitydeviceswith
poweredsimpletilt20°seechapter6.7.8Replacing
batteries(Poweredsimpletilt20°),page34.
CAUTION!
Riskofinjuryandmaterialdamagesifbatteries
arehandledimproperly
Installationofnewbatteriesmayonlybecarried
outbyauthorisedspecialists.
–Observewarninginformationonbatteries.
–Onlyusebatteryversionsstatedinthe
specications.
CAUTION!
Riskofreandburnsifbatteryterminalis
bypassed
–Takegreatcaretomakesurethatbattery
terminalsarenevershortedwithtoolsor
mechanicalmobilitydeviceparts.
–Makesurethatbatteryterminalcapshavebeen
replacedifyouarenotworkingonbattery
terminals.
CAUTION!
Riskofcrushing
Thebatteriesareextremelyheavy.Thisresultsin
riskofinjurytoyourhands.Bearinmindthat
batteriesaresometimesveryheavy.
–Handlebatterieswithcare.
321532486-L