Invacare®TDX®SP2Series
6.7.10Removingthebatteries
CAUTION!
Riskofreandburnsifbatterypolesarebridged
–Whenreplacingthebatteriesthebatterypoles
MUSTNOTcomeintocontactwithmetalparts
ofthewheelchaircausingbridging.
–Besuretoreplacethebatterypolecapsafter
thebatterieshavebeenreplaced.
CAUTION!
Riskofreandburnsduetodamagetothe
batterycables
–Thebatterycablesandothercablesare
positionedinacableductabovethebatteries.
Thecableductprotectsthecablesagainst
crushingandotherdamage.Itmaynotbe
removed.
•11mmwrench
•Slottedscrewdriver
1.
Removetheside-mountedlegrestsiftted.A
center-mounted,manuallyadjustablelegrestshouldbe
eitherputinitstoppositionbyturningthespindleA
orremoved.
2.
Removethethumbscrewssecuringthefront
shroud/batteryretentionbrackettothewheelchairA.
3.Liftuptounhookthebatteryretentionbracketfromthe
wheelchairframeandremovethefrontshroud/battery
retentionbracketfromthewheelchair.
4.
CAUTION!
Riskofcrushing
Theseatcanfalldownafewcentimeters
whenremovingtheactuatorwithoutsecuring
theseat.
–Holdtheseatinpositionwhileremoving
theactuatorandthenloweritcarefully.
Onlyifasimpletiltisinstalled:
a.RemovetheSLretainerAwithaslottedscrewdriver
andremovetheboltB.
b.RemovetheAllenscrewsC.
5.
SlideoutthebatterytrayAwiththebatteries.
6.DisconnectthebatterystrapsB.
7.
Removetheterminalcoverfromthebatteryterminals
(1).
8.Firstundotheboltonthenegativeterminal(blackcable)
withthe11mmwrench.
9.Afterthis,undotheboltonthepositiveterminal(red
cable).
CAUTION!
Riskofcrushing
–Thebatteriesareextremelyheavy.Ensurethat
theydonotfalltothegroundwhentheyare
removedfromthechassis.
10.Installationtakesplaceinreverseorder.
11.Checkallvehiclefunctions.
12.Checkthenewbatterystatusandchargecompletely.
6.7.11Generalinstructionsonhandlingthebatteries
•Nevermixandmatchdifferentbatterymanufacturesor
technologies,orusebatteriesthatdonothavesimilar
datecodes.
361532486-L