User Guide
Optidrive Plus 3
GV
Compact
OEM AC Variable Speed Drive
0.75 – 1.5kW (1 – 2HP)
Installation and Operating Instructions
Для заказов : +7(499)707-11-20 Email: i@sp-t.ru
8-800-511-65-88 (Бесплатно по РФ)

Questions and Answers

  • C
    cheryl54Aug 23, 2025
    What to do if Invertek Drives Inverter trips on overload?
    • K
      Katelyn AndersonAug 23, 2025
      If your Invertek Drives Inverter trips on overload, check to see when the decimal points are flashing (drive in overload) and either increase acceleration rate or reduce the load. Also, check that the motor cable length is within specification. Ensure the motor nameplate parameters are correctly entered (P1-07, P1-08, and P1-09). If operating in Vector mode (P4-01 – 0 or 1), also check the motor power factor in P4-05. Ensure an autotune has been successfully completed for the connected motor. Finally, check the load mechanically to ensure it is free, and no jams, blockages or other mechanical faults exist.
  • M
    Michele TurnerSep 4, 2025
    What to do if measured motor inductance is too large in Invertek Drives Optidrive Plus 3GV Compact?
    • C
      Christopher EdwardsSep 4, 2025
      Ensure the motor is correctly connected and free from faults. Check that the power rating corresponds to the power rating of the connected drive.
  • P
    paulbrooksSep 3, 2025
    What to check if Invertek Drives Optidrive Plus 3GV Compact Inverter shows external trip?
    • M
      Melissa ReyesSep 3, 2025
      If your Invertek Drives Inverter shows an external trip (on digital Input 3), it means the normally closed contact has opened for some reason. If a motor thermistor is connected, check if the motor is too hot.
  • C
    courtneyhaleSep 1, 2025
    What causes phase imbalance in Invertek Drives Optidrive Plus 3GV Compact Inverter?
    • B
      Brandon BrewerSep 1, 2025
      Phase imbalance in your Invertek Drives Inverter is caused by the mains incoming supply voltage having an imbalance of >3% for over 30 seconds. Check the incoming supply and fuses.
  • R
    Regina HansonAug 31, 2025
    What to do if Invertek Drives Inverter shows under voltage on DC bus?
    • A
      Amber MckenzieAug 31, 2025
      This condition occurs routinely when power is switched off. If it occurs during running, check the power supply voltage.
  • L
    Leah PerkinsAug 29, 2025
    Why Invertek Drives Optidrive Plus 3GV Compact Inverter autotune failed?
    • D
      David ReillyAug 29, 2025
      The Invertek Drives Inverter autotune may fail because the measured motor stator resistance varies between phases. To solve this, ensure the motor is correctly connected and free from faults. Check the windings for correct resistance and balance.
  • C
    Chad SimsAug 27, 2025
    What causes heatsink over temperature in Invertek Drives Optidrive Plus 3GV Compact Inverter?
    • C
      Christian LongAug 27, 2025
      A heatsink over temperature in your Invertek Drives Inverter can be caused by the drive's ambient temperature. Additional space or cooling may be required.
  • N
    Nicholas BrayAug 27, 2025
    What causes brake channel over current in Invertek Drives Inverter?
    • C
      Crystal NunezAug 27, 2025
      A brake channel over current in your Invertek Drives Inverter is caused by over current in the brake resistor circuit. To resolve this, check the cabling to the brake resistor and the brake resistor value. Ensure minimum resistance values from the rating tables are observed.
  • V
    Vanessa GarciaAug 25, 2025
    How to fix fast over current trip on Invertek Drives Optidrive Plus 3GV Compact Inverter?
    • V
      Vicki GibsonAug 25, 2025
      To address a fast over current trip on your Invertek Drives Inverter, start by checking the wiring to the motor for phase-to-phase or phase-to-earth short circuits. Next, assess the drive's ambient temperature to determine if additional space or cooling is needed. Finally, ensure the drive is not being forced into an overload condition.

Invertek Drives Optidrive Plus 3GV Compact Specifications

General IconGeneral
Power Range0.75kW to 22kW
Enclosure RatingIP20
Cooling MethodFan Cooled
Overload Capacity150% for 60 seconds
Input Voltage3-phase 380-480V AC
Control MethodV/f, Vector Control
Output Frequency0-400Hz
Communication ProtocolsModbus RTU, CANopen
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overload, Short Circuit, Phase Loss
Ambient Temperature-10°C to +40°C
Humidity95% RH (non-condensing)
AltitudeUp to 1000m (derating above 1000m)
Braking TransistorOptional

Related product manuals