Details the STAR connection for dual voltage motors, often used for small motors up to 3kW.
Details the DELTA connection for dual voltage motors, suitable for lower voltage ratings.
Lists key parameters for basic operation, including frequency, acceleration, voltage, current, and command source.
Lists parameters for Autotune, including menu access, motor voltage, current, frequency, speed, and control mode.
Procedure to set parameter P-52 and initiate the Autotune process for motor model building.
Details the Autotune process, noting motor excitation noise and completion feedback.
Parameters required for potentiometer speed control: menu access and analogue input signal format.
Wiring instructions for connecting a potentiometer to the AI1 terminal for variable speed control.
Parameters for switch control: command source, menu access, and digital input function for run/stop.
Wiring diagram for a 3-position switch to control forward, reverse, and stop operations.
Parameters for separate switches: command source, menu access, and digital input function for run/stop/direction.
Wiring diagrams for two 2-position switches: one for Run/Stop, another for Forward/Reverse direction.
Parameters for 3-wire control: command source, menu access, and digital input function for pushbuttons.
Wiring diagrams for three pushbuttons: normally closed for Stop, normally open for Run Forward/Reverse.
Parameters for dynamic braking: menu access and brake chopper enable settings.
Wiring instructions for connecting a brake resistor to the inverter's + and BR terminals for energy dissipation.
Procedure to reset all parameters to factory defaults using a three-button combination on the keypad.
Confirmation step for the factory reset process by pressing the stop key.
Guide to setting parameter P-14 to unlock extended or advanced parameter menus post-reset.
Details the STAR connection for dual voltage motors, often used for small motors up to 3kW.
Details the DELTA connection for dual voltage motors, suitable for lower voltage ratings.
Lists key parameters for basic operation, including frequency, acceleration, voltage, current, and command source.
Lists parameters for Autotune, including menu access, motor voltage, current, frequency, speed, and control mode.
Procedure to set parameter P-52 and initiate the Autotune process for motor model building.
Details the Autotune process, noting motor excitation noise and completion feedback.
Parameters required for potentiometer speed control: menu access and analogue input signal format.
Wiring instructions for connecting a potentiometer to the AI1 terminal for variable speed control.
Parameters for switch control: command source, menu access, and digital input function for run/stop.
Wiring diagram for a 3-position switch to control forward, reverse, and stop operations.
Parameters for separate switches: command source, menu access, and digital input function for run/stop/direction.
Wiring diagrams for two 2-position switches: one for Run/Stop, another for Forward/Reverse direction.
Parameters for 3-wire control: command source, menu access, and digital input function for pushbuttons.
Wiring diagrams for three pushbuttons: normally closed for Stop, normally open for Run Forward/Reverse.
Parameters for dynamic braking: menu access and brake chopper enable settings.
Wiring instructions for connecting a brake resistor to the inverter's + and BR terminals for energy dissipation.
Procedure to reset all parameters to factory defaults using a three-button combination on the keypad.
Confirmation step for the factory reset process by pressing the stop key.
Guide to setting parameter P-14 to unlock extended or advanced parameter menus post-reset.
| Output Voltage | 0 to input voltage |
|---|---|
| Protection Rating | IP20 |
| Altitude | Up to 1000m without derating |
| Output Frequency | 0-500 Hz |
| Overload Capacity | 150% for 60 seconds |
| Cooling Method | Fan cooled |
| Input Voltage | 200-240V, 380-480V |
| Control Method | Sensorless Vector Control |
| Operating Temperature | -10°C to +50°C |
| Humidity | 95% RH (non-condensing) |
| Protection Features | Over voltage, under voltage, over current, over temperature, short circuit, earth fault |
| Communication Options | Modbus RTU |
| Braking | Dynamic Braking Transistor standard |