Goodrive300-01 inverter for air compressor Function parameters
-75-
Detailed instruction of parameters
Digital input
terminals state
Display current switch input terminals state of the
inverter
Range: 0000~00FF
Digital output
terminals state
Display current switch output terminals state of the
inverter
Range:0000~000F
Display the adjustment through the keypad of the
inverter.
Range: 0.00Hz~P00.03
Display the torque reference, the percentage to the
current rated torque of the motor.
Setting range: -300.0%~300.0% (motor rated
current)
Display the current linear speed of the inverter
Range: 0~65535
Display the current length of the inverter
Range: 0~65535
Display the current counting value of the inverter
Range: 0~65535
Display analog AI1 input signal
Range: 0.00~10.00V
Display analog AI2 input signal
Range: 0.00~10.00V
Display analog AI3 input signal
Range: -10.00~10.00V
Display PT100 input signal
Range: 0.00~10.00V
Display PID reference value
Range: -100.0~100.0%
Display PID feedback value
Range: -100.0~100.0%
Power factor of
the motor
Display the current power factor of the motor
Range: -1.00~1.00
Display the current running time of the inverter
Range: 0~65535min
Simple PLC and
current step of
multi-step speed
Display simple PLC and current step of multi-step
speed Range: 0~15