Goodrive300-LIFT series inverter Function parameters
-50-
Detailed instruction of parameters
analog output. When the output value exceeds
the range of set maximum or minimum output, it
will count according to the low-limit or upper-limit
output.
When the analog output is current output, 1mA
equals to 0.5V.
In different cases, the corresponding analog
output of 100% of the output value is different.
See each application for detailed information.
Setting range of P06.11: -300.0%–P06.13
Setting range of P06.12: -0.00V–10.00V
Setting range of P06.13: -P06.11–300.0%
Setting range of P06.14: -0.00V–10.00V
Setting range of P06.15: -0.000s–10.000s
Setting range of P06.16: -300.0%–P06.18
Setting range of P06.17: -0.00–50.00kHz
Setting range of P06.18: -P06.16–300.0%
Setting range of P06.19: -0.00–50.00kHz
Setting range of P06.20: -0.000s–10.000s
AO1 output of
upper limit
HDO output of
lower limit
HDO output of
upper limit
P07 Group Human-machine interface
Ones place:
0: No operation
1: Upload function parameters to the keypad
from machine
2: Download function parameters (including
motor parameters) from the keypad to machine.
3: Download function parameters (excluding the
motor parameters of P02) from the keypad to
machine.
4: Download function parameters (including only
motor parameters of P02) from the keypad to