Goodrive300-LIFT series inverter Function parameters
-57-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P07.61
Output terminals
state at last but
one fault
0
P07.62
Reserved
065535
0
P07.63
Reserved
065535
0
P08 Group Enhanced function
P08.00
Analogic
weighing input
0: None
1: AI1
0
P08.01
Pre-torque offset
0.0100.0%
45.0%
P08.02
Gain at drive
side
0.0007.000
2.000
P08.03
Gain at braking
side
0.0007.000
2.000
P08.04
Brake close
delay
0.005.00s
0.10s
P08.05
Brake switch-off
delay
0.005.00s
0.10s
P08.06
Brake feedback
detection time
0.05.0s
2.0s
P08.07
Brake fault
action
0: Report the fault and stop
1: Stop without fault reporting
0
P08.08
Contactor
feedback
detection time
0.005.00s
2.0s
P08.09
Contactor fault
action
0: Report the fault and stop
1: Stop without fault reporting
0
P08.10
Braking
threshold
voltage
320.0750.0V
700.0V
P08.11
Auto fault reset
count
010
(OUT and OC do not allow auto fault reset.)
0