Goodrive300-LIFT series inverter Commissioning guidelines
-88-
Function
code
Name
Recommended
value
Remarks
P05.12
HDI terminal
3
Maintenance
P06.01
Y output
1
Running feedback output
P06.04
Relay 1 output
4
Fault output (EO)
P06.05
Relay 2 output
7
Brake control (FC)
P06.06
Relay 3 output
8
Contactor control (TC)
P08.04
Brake close delay
0.1s
P08.05
Brake release delay
0.10s
P08.06
Brake feedback
detection time
2.0
P08.08
Contactor feedback
detection time
2.0
P08.14
Braking frequency
0.05Hz
P08.15
Inverter stop delay
0.10s
P08.30
Open-loop start
brake open
frequency of
asynchronous motor
0.0 Hz
P09.00
Multi-step speed 0
0 (speed of zero)
Set based on user control requirements.
The speed of step 0 is set to 0 m/s.
P09.01
Multi-step speed 1
Leveling speed
P09.02
Multi-step speed 2
Emergency speed
P09.03
Multi-step speed 3
Common low
speed
P09.04
Multi-step speed 4
Inspection speed
P09.05
Multi-step speed 5
Reserved
P09.06
Multi-step speed 6
Reserved
P09.07
Multi-step speed 7
Common high
speed
P09.09
S-curve ACC start
segment duration
2.0s
Adjusted based on onsite
commissioning
P09.10
S-curve ACC end
segment duration
2.0s
P09.11
ACC time
2.0s
P09.12
S-curve DEC start
segment duration
2.0s
P09.13
S-curve DEC end
2.0s