Goodrive350 series high-performance multi-function inverter Chapter 5
-100-
Function
code
Name
Detailed parameter description
Default
value
P10.28
Multi-step speed 13
-100.0100.0%
0.0%
P10.29
Running time of 13
th
step
0.06553.5s (min)
0.0s
P10.30
Multi-step speed 14
-100.0100.0%
0.0%
P10.31
Running time of 14
th
step
0.06553.5s (min)
0.0s
P10.32
Multi-step speed 15
-100.0100.0%
0.0%
P10.33
Running time of 15
th
step
0.06553.5s (min)
0.0s
P10.36
PLC restart mode
0: Restart from the first section
1: Continue running at the frequency
when interruption occurred
0
P10.34
Acceleration/deceleration
time of 07 stage of simple
PLC
0x00000XFFFF
0000
P10.35
Acceleration/deceleration
time of 815 stage of simple
PLC
0x00000XFFFF
0000
P05.01
P05.09
Digital input function
23: Simple PLC stop reset
24: Simple PLC pause
25: PID control pause
P06.01
P06.04
Digital output function
16: Simple PLC stage reached
17: Simple PLC cycle reached
P17.00
Set frequency
0.00HzP00.03 (max. output frequency)
0.00Hz
P17.27
Simple PLC and current
stage number of multi-step
speed
015
0
5.5.14 Multi-step speed running
Set the parameters used in multi-step speed running. GD350 inverter can set 16-step speeds, which
are selectable by multi-step speed terminals 14, corresponding to multi-step speed 0 to multi-step
speed 15.