Goodrive350 series high-performance multi-function inverter Chapter 6
-145-
Function
code
Name
Detailed parameter description
Default
value
Modi
fy
P04.45
Enable/disable IF
mode of
asynchronous
motor 2
01
0
P04.46
IF current setting
of asynchronous
motor 2
0.0200.0%
120.0%
P04.47
IF proportional
coefficient of
asynchronous
motor 2
05000
650
P04.48
IF integral
coefficient of
asynchronous
motor 2
05000
350
P04.49
IF mode cut-off
frequency
threshold of
asynchronous
motor 2
0.0020.00Hz
10.00Hz
P04.50
Reserved
variables
065535
0
P04.51
Reserved
variables
065535
0
P05 group Input terminals
P05.00
HDI input type
0x000x11
Ones: HDIA input type
0: HDIA is high-speed pulse input
1: HDIA is digital input
Tens: HDIB input type
0: HDIB is high-speed pulse input
1: HDIB is digital input
0
P05.01
Function of S1
terminal
0: No function
1: Forward running
2: Reverse running
3: Tri-line running control
4: Forward jogging
5: Reverse jogging
1
P05.02
Function of S2
terminal
4
P05.03
Function of S3
terminal
7