Goodrive350 series high-performance multi-function inverter Chapter 6
-180-
Function
code
Name
Detailed parameter description
Default
value
Modi
fy
P11.21
Proportional
coefficient of
voltage regulator
during
overvoltage stall
01000
60
P11.22
Integral
coefficient of
voltage regulator
during
overvoltage stall
01000
10
P11.23
Proportional
coefficient of
current regulator
during
overvoltage stall
01000
60
P11.24
Integral
coefficient of
current regulator
during
overvoltage stall
02000
250
P11.25
Enable inverter
overload integral
0: Disable
1: Enable
0
P11.26
P11.27
Reserved
variables
065536
0
P12 group Parameters of motor 2
P12.00
Type of motor 2
0: Asynchronous motor
1: Synchronous motor
0
P12.01
Rated power of
asynchronous
motor 2
0.13000.0kW
Depend
on model
P12.02
Rated frequency
of asynchronous
motor 2
0.01HzP00.03 (max. output frequency)
50.00Hz
P12.03
Rated speed of
asynchronous
motor 2
136000rpm
Depend
on model
P12.04
Rated voltage of
asynchronous
01200V
Depend
on model

Table of Contents