SPC Series Solar Pump Inverter Installation guidelines
-9-
has been idled for a long time, install an external heating device
before the use to eliminate the freeze inside the inverter. Otherwise,
the inverter may be damaged.
-40°C–70°C, with the air temperature change rate less than 1°C/minute.
Install the inverter in a place:
Away from electromagnetic radiation sources;
Away from oil mist, corrosive gases, and combustible gases
Without the chance for foreign objects such as metal powder, dust,
oil and water to fall into the inverter (do not install the inverter onto
combustible objects such as wood)
Without radioactive substances and combustible objects;
Without hazard gases and liquids;
With low salt content
Without direct sunlight
Ingress
protection
(IP) rating
When the altitude is higher than 2000m but lower than 3000m,
derate the inverter by 1% for every increase of 100m.
When the altitude is higher than 3000m but lower than 5000m,
consult us for technical consulting. It is not recommended to use the
inverter when the altitude exceeds 5000m.
Install the inverter vertically to ensure good heat dissipation performance.
Note:
The inverter needs to be installed at a clean and ventilated environment according to
the housing IP rating.
The cooling air must be clean enough and free from corrosive gases and conductive
dust.