SPC Series Solar Pump Inverter Function parameter list
-38-
P14 group Serial communication
Local
communication
address
0: 1200BPS
1: 2400BPS
2: 4800BPS
3: 9600BPS
4: 19200BPS
5: 38400BPS
6: 57600BPS
0: No check (N, 8, 1) for RTU
1: Even check (E, 8, 1) for RTU
2: Odd check (O, 8, 1) for RTU
3: No check (N, 8, 2) for RTU
4: Even check (E, 8, 2) for RTU
5: Odd check (O, 8, 2) for RTU
Communicatio
n response
delay
Communicatio
n timeout time
Transmission
fault
processing
0: Report an alarm and coast to stop
1: Keep running without reporting an
alarm
2: Stop in enabled stop mode without
reporting an alarm (applicable only to
communication mode)
3: Stop in enabled stop mode without
reporting an alarm (applicable to any
mode)
Communication
processing
action
0x000–0x111
Ones place:
0: Respond to write operations
1: Not respond to write operations
Tens place:
0: Password protection is invalid.