SPC Series Solar Pump Inverter Function parameter list
-35-
6.2 Function parameters special for solar water pump
P11 group Protection
Function
code
Name
Description
Default
Modify
P11.01
Frequency
decrease at
sudden power
loss
0: Disable
1: Enable
0
P11.02
Frequency
decrease ratio
at sudden
power loss
0.00HzP00.03/s
If the bus voltage drops to the sudden
frequency decreasing point due to the
power loss of the grid, the inverter begins
to decrease the running frequency
according to P11.02 to make the motor in
power generation state. The regenerative
power can maintain the bus voltage to
ensure normal running of the inverter
until the recovery of power.
10.00Hz/
s
P11.05
Current limit
selection
0x000x12
Ones place: Current limit action selection
0: Invalid
1: Valid
2: Invalid during DEC
Tens: Hardware current limit overload
alarm selection
0: Valid
1: Invalid
0x01
P11.06
Automatic
current limit
threshold
50.0200.0%
120.0%
P11.07
Frequency
decrease ratio
in current
limiting
0.0050.00Hz/s
10.00Hz/
s
P11.08
Inverter/motor
OL/UL
pre-alarm
selection
0x00000x1131
Ones place:
0: Motor OL/UL pre-alarm, relative to the
motor rated current
0x0000