SPC Series Solar Pump Inverter Function parameter list
-23-
P01 group Start and stop control
Function
code
Name
Description
Default
Modify
P01.08
Stop mode
0: Decelerate to stop. When a stop
command takes effect, the inverter
lowers output frequency based on the
DEC mode and the defined DEC time;
when the frequency drops to 0Hz, the
inverter stops.
1: Coast to stop. When a stop command
takes effect, the inverter stops output
immediately. and the load coasts to stop
according to mechanical inertia.
0
P01.18
Terminal-base
d running
command
protection at
power-on
0: The terminal running command is
invalid at power-on
1: The terminal running command is valid
at power-on
1
P01.21
Power-off
restart
selection
0: Disable restart
1: Enable restart
1
P02 group Parameters of motor 1
Function
code
Name
Description
Default
Modify
P02.00
Motor type
0: Asynchronous motor (AM)
1: Synchronous motor (SM)
1
P02.01
Rated power of
AM
0.13000.0kW
Used to set AM
parameters.
To ensure the control
performance, set
P02.01P02.05
correctly according to
the information on the
nameplate of the AM.
The inverter provides
Model
depended
P02.02
Rated
frequency of
AM
0.01HzP00.03
110.00Hz