SPC Series Solar Pump Inverter Function parameter list
-28-
Function
code
Name
Description
Default
Modify
P04.10
Low-frequency
oscillation
control factor of
motor 1
In space voltage vector control mode, the
motor, especially the large-power motor,
may experience current oscillation at
certain frequencies, which may cause
unstable motor running, or even inverter
overcurrent. You can adjust the two
function codes properly to eliminate such
phenomenon.
Setting range of P04.10 and P04.11: 0
100
Setting range of P04.12: 0.00HzP00.03
(Max. output frequency)
10
P04.11
High-frequency
oscillation
control factor of
motor 1
10
P04.12
Oscillation
control
threshold
30.00Hz
P04.36
Reactive
closed-loop KP
05000
50
P04.37
Reactive
closed-loop KI
05000
50
P05 group Input terminals
Function
code
Name
Description
Default
Modify
P05.01
Function of S1
0: No function
1: Run forward
2: Run reversely
3: Reserved
4: Jog forward
5: Jog reversely
6: Coast to stop
7: Reset faults
8: Pause running
9: External fault input
1029: Reserved
30: Disable ACC/DEC
3133: Reserved
34: DC braking
35: Reserved
36: Switch the running command channel
to keypad
1