SPC Series Solar Pump Inverter Function parameter list
-19-
6 Function parameter list
The function group numbers correspond to the level-1 menus, the function codes
correspond to the level-2 menus, and the function parameters correspond to the level-3
menus.
The function code table contains:
Column 1 "Function code ": Code of the function group and parameter
Column 2 "Name": Full name of the function parameter
Column 3 "Description": Description of the function parameter. If the value is detected or
recorded, the value cannot be restored to the factory setting.
Column 4 "Default": Initial value set in factory.
Column 5 "Modify": Whether the parameter can be modified, and conditions for the
modification
"○" indicates that the value of the parameter can be modified when the inverter is in
stopped or running state.
"◎" indicates that the value of the parameter cannot be modified when the inverter is in
running state.
"●" indicates that the value of the parameter is detected and recorded, and cannot be
modified.
Note: The inverter automatically checks and constrains the modification of parameters,
which helps prevent incorrect modifications.
6.1 Function parameters related to control
P00 group Basic functions
0: SVC mode 0
No need to install encoders. Applicable to
scenarios with requirements for low
frequency, great torque, and high speed
control accuracy. Relative to SVC mode
1, SVC mode 0 is more applicable to the
scenarios requiring small power.
1: SVC mode 1
Applicable to high-performance
scenarios, featuring high rotation and