SPC Series Solar Pump Inverter Function parameter list
-32-
Sequence of
switching
running-comm
and channels
by pressing
QUICK/JOG
When P07.02=6, set the sequence of
switching running-command channels by
pressing this key.
0: Keypad→Terminal→Communication
1: Keypad←→Terminal
2: Keypad←→Communication
3: Terminal←→Communication
Stop function
validity of
STOP/RST
Used to specify the stop function validity
of STOP/RST. For fault reset,
STOP/RST is valid in any conditions.
0: Valid only for keypad control
1: Valid both for keypad and terminal
control
2: Valid both for keypad and
communication control
3: Valid for all control modes
Control board
software
version
0: No fault
1–3: Reserved
4: Overcurrent during acceleration (OC1)
5: Overcurrent during deceleration (OC2)
6: Overcurrent during constant speed