4.4.4.8 Module Installation Sequence
A SEQUENCE NUMBER is assigned to gateway modules based on the sequence of registration with
the system, refer to the iPECS Admin & Program Manual for further details. This SEQUENCE
NUMBER determines the logical CO Line and station numbers assigned in the system database.
Although the SEQUENCE NUMBER in the database can be changed, connecting the gateway
Modules to the iPECS in the desired sequence based on type of Module is recommended. The
Module SEQUENCE NUMBER can be easily established at installation by controlling the order of
connection of the Module’s LAN port to the system.
Station numbers are also assigned consecutively based on the order of connection to the system.
Since the first phone installed is assigned as the Admin Station (station number 100), it is
recommended an LIP Phone be connected to the system prior to installing any SLT gateway
Module.