33YLS-K
Item Designation Item Designation
1 Process fiber 4 Protective glass
2 Protective conduit 5 Protective cap
3 Quartz block
Depending on the ordered configuration and laser power, different fiber
connector types are delivered that are designed for optics and laser out-
puts. The fiber connector types differ in their diameters and shape of
the mounting surfaces, core diameters of connected fibers and the way
they are assembled in the optics. The existing fiber connector types are
shown in the following figure. The exact dimensions of the respective
fiber connectors can be found in the appendix.
Figure7: Overview: fiber connectors
Fiber con-
nector type
Fiber core diameter [µm] Optional
protective
conduit
Protective
glass option
LC-8 100, 150, 200, 300, 400, 600,
800, 1000
Yes Yes
HLC-8 100, 150, 200, 300, 400, 600,
800, 1000
Yes Yes
LCA 100, 150, 200, 300, 400, 600 No Yes
For recommendations on the process-dependent use of the protective
conduit or the protective glass, see the section Clean fiber connectors
[}116].
| Device description