ARMY TM 9-2815-254-24
AlR FORCE TO 38G1-94-2
Table 3-2. Troubleshooting - Continued
18.
BATTERY CHARGED AMMETER SHOWS EXCESSIVE CHARGING AFTER PROLONGED PERIOD.
Step 1.
Check for defective batteries.
a
Test batteries. Refer to end item maintenance manual. If batteries not defective, do step 2.
b. Replace batteries. Refer to and item maintenance manual.
Step 2.
Test for defective battery charging alternator.
fective, do step 3.
a. Inspect and test battery charging alternator. Refer to paragraph 3-24.3. If alternator not de-
b. Repair or replace battery charging alternator. Refer to paragraph 3-24.
step 3.
Check for short in charging circuit.
If shorted, repair charging circuit. Refer to end item maintenance manual.