Technical Specification
Note: 1. Models without emergency stop module (i.e. AC contactor not in-
cluded), other AC input voltage ranges are required for customization. Models
without emergency stop module and assembled to the cabinet, with AC input
voltage in the range of 198~264V, need to be customized while derating by
50%. Models with emergency stop module (including AC contactor) only sup-
port 380VAC±10% for standard AC input voltage, 480VAC±10% voltage is re-
quired for customization.
6.1.1.2 IT6010D-80-300
Parameter IT6010D-80-300
Rated value
Output Voltage
0~80V
( 0 ℃-50 ℃) Output Current
0~300A
Output Power
0~10kW
Line Regulation Voltage
≤0.01%FS
±(%of Output+Offset)
Current ≤0.05%FS
Load Regulation Voltage
≤0.02%FS
±(%of Output+Offset)
Current ≤0.05%FS
Setup Resolution
Voltage
0.001V
Current 0.01A
Power 0.001kW
Read Back Resolution
Voltage
0.001V
Current 0.01A
Power 0.001kW
Setup Accuracy Voltage
≤0.02% + 0.02%FS
( within 12 months, 25℃
±5℃)
Current ≤0.1% + 0.1%FS
±(%of Output+Offset)
Power ≤0.5% + 0.5%FS
Read Back Accuracy Voltage
≤0.02% + 0.02%FS
( within 12 months, 25℃
±5℃)
Current ≤0.1% + 0.1%FS
±(%of Output+Offset)
Power ≤0.5% + 0.5%FS
Ripple Voltage ≤120mVpp(MAX: ≤300mVpp)
(20Hz -20MHz)
Current ≤0.1%FS RMS
Setup Temperature
Coefficient
Voltage
≤50PPM/℃
Copyright © Itech Electronic Co., Ltd.