Technical Specification
6.1.3.3 IT6018D-500-120
Parameter IT6018D-500-120
Rated value ( 0 ℃-50 ℃)
Output Voltage
0~500V
Output Current
0~120A
Output Power
0~18kW
Line Regulation Voltage
≤0.01%FS
±(%of Output+Offset)
Current ≤0.05%FS
Load Regulation Voltage
≤0.02%FS
±(%of Output+Offset)
Current ≤0.05%FS
Setup Resolution
Voltage
0.01V
Current 0.01A
Power 0.001kW
Read Back Resolution
Voltage
0.01V
Current 0.01A
Power 0.001kW
Setup Accuracy Voltage
≤0.02% + 0.02%FS
( within 12 months, 25℃
±5℃)
Current ≤0.1% + 0.1%FS
±(%of Output+Offset)
Power ≤0.5% + 0.5%FS
Read Back Accuracy Voltage
≤0.02% + 0.02%FS
( within 12 months, 25℃
±5℃)
Current ≤0.1% + 0.1%FS
±(%of Output+Offset)
Power ≤0.5% + 0.5%FS
Ripple Voltage ≤200mVpp(MAX: ≤500mVpp)
(20Hz -20MHz)
Current ≤0.1%FS RMS
Setup Temperature
Coefficient
Voltage
≤50PPM/℃
±(%of Output/℃+Offset)
Current ≤200PPM/℃
Read Back Temperature
Coefficient
Voltage
≤50PPM/℃
±(%of Output/℃+Offset)
Current ≤200PPM/℃
Rise Time( no load ) Voltage
≤15ms
Rise Time( full load ) Voltage
≤30ms
Fall Time( no load ) Voltage
≤1s
Copyright © Itech Electronic Co., Ltd.
143