EasyManua.ls Logo

ITech IT6000D Series

ITech IT6000D Series
178 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Specification
Parameter IT6012D-800-50
Power Factor 0.99
Storage Temperature
-10℃~70
Protective Function
OVP, OCP, OPP, UVP, UCP, OTP, Vsense protection
Standard Interface
Standard: USB, CAN, LAN, VCP; optional: GPIB, analog card (in-
cludes RS232), fiber optic socket
Isolation ( output to ground)
1500V
Working Temperature
050
Dimension ( mm) 483mm(W)*801.61mm(D)*151.3mm(H)
Weight( net)
30KG
Note:
1. Models without emergency stop module (i.e. AC contactor not included), other AC input volt-
age ranges are required for customization. Models without emergency stop module and as-
sembled to the cabinet, with AC input voltage in the range of 198~264V, need to be customized
while derating by 50%. Models with emergency stop module (including AC contactor) only sup-
port 380VAC±10% for standard AC input voltage, 480VAC±10% voltage is required for
customization.
6.1.4.3 IT6018D-800-75
Parameter IT6018D-800-75
Rated value
Output Voltage
0800V
( 0 -50 ) Output Current
075A
Output Power
018kW
Line Regulation Voltage
≤0.01%FS
±(of Output+Offset)
Current ≤0.05%FS
Load Regulation Voltage
≤0.02%FS
±(of Output+Offset)
Current ≤0.05%FS
Setup Resolution
Voltage
0.01V
Current 0.01A
Power 0.001kW
Read Back Resolution
Voltage
0.01V
Current 0.01A
Power 0.001kW
Setup Accuracy Voltage
≤0.02% + 0.02%FS
Copyright © Itech Electronic Co., Ltd.