Basic Operation
1. Press the composite keys [Shift]+[P-set] (System) on the front panel to en-
ter the system menu.
2. Press the Up/Down key or turn the knob to select the PowerOn and press
[Enter].
3. Press the Left / Right key or turn the knob to adjust the value of this
parameter.
Reset: Default value, indicates when the instrument is powered on, the
instrument will initialize some parameter settings or state.
The affected parameters and the reset information are as shown in the
following table.
Table 5–1 Initial value of the parameter
Category Parameter Initial Value
Main
interface
Voltage setting: Vs One percent of the
rated voltage of the
instrument
Current setting: Is One percent of the
rated current of the
instrument
Upper limit of voltage: Vh, and
lower limit of voltage: Vl
Upper limit value: One
percent of the rated
voltage of the
instrument
Lower limit value: 0
Upper limit of current: I+, and
lower limit of current: I-
One percent of the
rated current of the
instrument
Upper limit of power: P+, and
lower limit of power: P-
Rated power value of
the instrument
[On/Off] status Off
Config
menu
Mode CV
Speed High
Copyright © Itech Electronic Co., Ltd.
106

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6018C-1500-30 and is the answer not in the manual?

ITech IT6018C-1500-30 Specifications

General IconGeneral
BrandITech
ModelIT6018C-1500-30
CategoryPower Supply
LanguageEnglish

Related product manuals