Power Supply Function
The trigger method of the battery test is consistent with the trigger method
of the List function, that is, the List trigger source is also effective for the
Battery function.
If you want to stop running during the battery test, you can do the following:
Press the composite keys [Shift]+[I-set] (Function) on the front panel to enter
the function menu.
At this point, the interface will prompt whether to stop the running of the Func-
tion (FUNCTION STOP?), you can press the Left/Right key to select Yes, then
the current running will be stopped, and the Function menu item will be dis-
played, you can re-enter the Function menu for editing; if No is selected, it
means that the current running will not be stopped, and the main interface of the
system is displayed.
4.6.3 Built-in Waveform Function
The IT6000C series power supply supports built-in waveforms for user to exe-
cute the test directly. The protocols/standards involved in the built-in waveforms
include the following:
• DIN40839
• ISO16750-2
• ISO21848
• SAEJ1113–11
• LV124
The following is a general overview of this function menu, and the detailed pa-
rameters of the waveform corresponding to each protocol/standard can be
found in the corresponding chapter.
Road-
Vehicles
Vehicle waveform function menu
DIN40839
Evaluation of automotive starting
waveform
ISO16750-2
Simulate the waveform to verify the
anti-interference performance of the au-
tomotive electronics’ products.
ISO21848 42V Road vehicles — Electrical and
electronic equipment for a supply volt-
age of 42 V — Electrical loads
Copyright © Itech Electronic Co., Ltd.